Hey ${desensitizationEmail}, to make sure your account security, please verify your email address here. Verify Email
For your account security, please link your email. Verify Email
Your Credit, Our Guarantee! Enjoy CJ's Special Service of Ordering First, Pay Later Designed for the Special You.
Hey ${desensitizationEmail}, to make sure your account security, please verify your email address here. Verify Email
For your account security, please link your email. Verify Email
Your Credit, Our Guarantee! Enjoy CJ's Special Service of Ordering First, Pay Later Designed for the Special You.
Download Images
Offer by Supplier: contecmedical
Contact
Returns & Refunds
Eligible for refunds within 30 days of receiving products. View details
Description 
Buyer Reviews (-)
Merchant Comments (-)
Description
Material
Plastic
Product Attributes
Electronic
Package Size
380*340*240(1mm)

Introduction

It is a multi - purpose test device for testing NIBP Monitor adopted Oscillometry. Concise and elegant in appearance, easy and convenient to operate, and it can generate the pressure up to 400mmHg (53.3 kPa) by the built-in air pump. With the functions of dynamic BP simulation under several conditions, static pressure calibration, automatic leak test and over-pressure relief test, which can quickly and accurately analyze each performance of NIBP Monitor.


Functions

1)Pressure leak test
2)Over-pressure relief test
3)BP simulation under standard condition
4)BP simulation under patient condition
5)BP simulation under arrhythmia condition
6)BP simulation under respiratory interference condition
7)BP simulation of neonate
8)Wrist BP simulation
9)User-defined BP simulation
10)System setting function.
11)The parameters set can be stored.
12)ON/OFF function
13)Dynamic BP simulation


Performance

BP simulation range:
Systolic pressure: 2.7 kPa (20 mmHg) ~ 40.0 kPa (300 mmHg)
Diastolic pressure: 1.3kPa (10 mmHg) ~ 33.3 kPa (250mmHg)
Pulse volume: 0.1 cc ~ 2.4 cc
HR range: 30 bpm ~ 250 bpm; pulse volume > 2.00 cc, maximum HR: 200 bpm
HR accuracy: ± 1 bpm (except patient condition, arrhythmia and respiratory disturbance)
Under patient condition:
Weak pulse, tachycardia, obese, geriatric: ±(preset value 1%+1)bpm
Moderate exercise: ±(preset value 1.5%+1)bpm
Strenuous exercise: ±(preset value 3%+1)bpm
Pressure measurement:
Range: 0kPa (0 mmHg) ~ 53.3 kPa (400 mmHg)
Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi
Accuracy:
0 kPa (0 mmHg) ~ 40.0 kPa (300 mmHg), ± (0.5 % of reading + 0.1) kPa or ± (0.5% of reading +1) mmHg
40.1 kPa (301 mmHg) ~ 53.3 kPa (400mmHg), ± 2% of reading
Pressure leak test
Generate a pressure up to 400 mmHg by the built-in air pump. It always displays the peak pressure and the real-time pressure. Leak rate is displayed after 10 seconds.
Over-pressure relief test
Generate a pressure up to 400 mmHg by the built-in air pump, it displays peak pressure.
Pressure source:
Output range: 6.7 kPa (50 mmHg) ~ 53.3 kPa(400 mmHg)
Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi
Deviation between target pressure and actual pressure: ± 1.3 kPa (± 10 mmHg) in range of 13.3 kPa (100 mmHg) ~ 53.3 kPa (400 mmHg) with a minimum volume of 300 cc
Airtightness
Total airtightness: < 0.3 kPa/min (2.25 mmHg/min) under “OFF” state
Airtightness of built-in cuff: 0.27 kPa/min (2 mmHg/min)
BP simulation preset value configuration table


BP simulation BP preset value BP HR Pulse volume
Standard BP simulation #1 120/80(93) 80bpm 0.68cc
#2 150/100(116) 0.65cc
#3 200/150(166) 0.60cc
#4 255/195(215) 0.55cc
#5 60/30(40) 0.75cc
#6 80/50(60) 0.71cc
#7 100/65(76) 0.69cc
BP simulation under patient condition
Healthy heart 120/80(93) 75bpm 0.68cc
Weak Pulse 110/80(90) 95bpm 0.50cc
Mild Exercise 140/90(106) 120bpm 1.00cc
Strenuous Exer 140/90(106) 162bpm 1.40cc
Obese 120/80(93) 90bpm 0.50cc
Geriatric 150/110(123) 95bpm 0.40cc
Tachycardia 120/105(110) 130bpm 0.40cc
Bradycardia 120/60(80) 45bpm 1.10cc
BP simulation under arrhythmia condition
Premature Atrial Contraction1 138/53(81) 80bpm 0.70cc


Premature Atrial Contraction2 144/64(90) 83bpm
Premature Ventricular Contraction 118/61(80) 83bpm
Atrial Fibrillation and PVC 139/72(94) 91bpm


BP simulation under respiratory interference condition
spontaneous breathing1 138/65(89) 104bpm 0.60cc
spontaneous breathing2 149/65(93) 105bpm
spontaneous breathing3 112/47(68) 86bpm
controlled breathing 132/44(73) 98bpm
BP simulation of neonate
#1 35/15(22) 120bpm 0.11cc
#2 60/30(40) 0.10cc
#3 80/50(60)
#4 100/70(80)
BP simulation of wrist cuff
#1 120/80(93) 80bpm 0.50cc
#2 160/100(120)
#3 80/55(63)
User-defined BP simulation[1] - - - -
Note[1]:Support 9 user-defined BP simulation modes. The following parameters can be defined by users:2.3.1.The value of diastolic pressure should be lower than systolic pressure, pulse volume and HR can not be set to the highest values (e.g., pulse volume ≤ 2.00cc, HR: 250 bpm; pulse volume > 2.00cc, HR: 200bpm).


Accessories

One User Manual
Two fuses
One power cord


Physical characteristic

Display: 4.3" 65 K color LCD display
Power supply: AC100 ~ 240 V 50/60 Hz, <60 VA
Environment temperature: + 5 ℃ ~ + 40 ℃
Relative humidity: < 90 %, non-condensing
Altitude: ≤ 3000 m
Atmospheric pressure: 80 kPa ~ 106 kPa
Dimension: 207 (L) × 220 (W) × 121 (H) mm
Weight: about 2.1 kg 

Buyer Review (-)
Merchant Comment (-)
Dropshipping
Customize

CONTEC MS200 NIBP Simulator Blood Pressure Monitor Accuracy Simulation Test

SKU: CJZN1712712-MS200
Free shipping
$639.00
Warehouse
Model(MS200)
  • MS200
QTY:
6,000g
Inventory: --
Estimated Processing Time:
1-3 days for 80% orders
Estimated Delivery Time:
--
Shipping Fee:
0.00
Too many attempts at shipping calculation. Please sign in before trying again. Sign In
Recommended Products
View More